Skip to main content
  • Research article
  • Open access
  • Published:

Detection and identification of enterohemorrhagic Escherichia coli O157:H7 and Vibrio cholerae O139 using oligonucleotide microarray

Abstract

Background

The rapid and accurate detection and identification of the new subtype of the pathogens is crucial for diagnosis, treatment and control of the contagious disease outbreak. Here, in this study, an approach to detect and identify Escherichia coli O157:H7 and Vibrio cholerae O139 was established using oligonucleotide microarray. We coupled multiplex PCR with oligonucleotide microarray to construct an assay suitable for simultaneous identification of two subtypes of the pathogens.

Results

The stx 1, stx 2 gene and uid A gene having the specific mutant spot were chosen as the targets for Escherichia coli O157:H7, and meanwhile the ctx A, tcp A, and LPSgt gene for Vibrio cholerae O139. The oligonucleotide microarray was composed of eight probes including negative control and positive control from 16S rDNA gene. The six primers were designed to amplify target fragments in two triplex PCR, and then hybridized with oligonucleotide microarray. An internal control would be to run a PCR reaction in parallel. Multiplex PCR did not produce any non-specific amplicons when 149 related species or genera of standard bacteria were tested (100% specificity). In addition, Escherichia coli O157:H7 and Escherichia coli O157:non-H7, Vibrio cholerae O139 and Vibrio cholerae O1 had been discriminated respectively. Using recombinant plasmid and target pathogens, we were able to detect positive hybridization signals with 102 copies/μL and 103 cfu/mL per reaction.

Conclusion

The DNA microarray assay reported here could detect and identify Escherichia coli O157:H7 and Vibrio cholerae O139, and furthermore the subtype was distinguished. This assay was a specific and sensitive tool for simultaneous detection and identification of the new subtype of two pathogens causing diarrhea in human.

Background

Escherichia coli O157:H7 and Vibrio cholerae O139 are lethal pathogens capable of causing severe infectious diseases, characterized by acute outbreak, and large scale prevalence. As the statistics from Ministry of Health People Public of China shown [1], many incidents related to diarrhea due to two pathogens happened in recent year. The control and prevention means were extremely effective, since two kinds of new serotypes appeared. Meanwhile the government had taken many measures for studying detection and therapy assay. Therefore, we developed an assay for detecting the new serotypes of two pathogens. E. coli O157:H7 is capable of causing severe clinical symptoms such as enterohemorrhage and hemolytic uremic syndrome [2, 3]. It can outbreak epidemically through the contamination of foods and water [4]. The pathogenicity of E. coli O157:H7 is related to various specific genes such as Shiga genes stx1, stx2 [5, 6] and β-glucuronidase gene uid A (gus A) [7, 8]. In some studies, stx genes were used to identify E. coli O157:H7 [9], but these genes existed in some O157: non-H7 serotypes, as well as some other types of pathogenic E. coli [10]. Therefore, mere detection of stx genes is not reliable for the purpose of identifying E. coli O157 serotype, and detection of specific genes to E. coli O157:H7 must be involved. The previous study also indicated that a strictly specific base mutation T93G occurs in the uid A gene of E. coli O157:H7 [6, 11]. As a result, nucleic acid hybridization was used to detect this conserved mutation spot T93G of uid A gene in order to discriminate O157:H7 from other stx-producing intestinal bacteria.

Vibrio cholerae O139 is a strain of bacterium discovered in 1992 [12]. It can result in severe infectious diseases mainly accompanying with symptoms of diarrhea, characterized by acute outbreak, rapid spread, broad affected area, and large scale prevalence [13]. It was indicated that Vibrio cholerae O139 derived from Vibrio cholerae serotype O1 [14, 15]. Both Vibrio cholerae O139 and Vibrio cholerae O1 have two principal virulence genes, ctx A and tcp A [16], yet they are different in the gene composition and sequence of LPSgt [17].

For a long time being, the traditional diagnosis of pathogenic E. coli O157:H7 and Vibrio cholerae O139 is mainly based on the conventional bacterial culture, which is a laborious and time-consuming procedure. It will take several days to obtain precise diagnostic results [18]. Therefore, it was very important to establish a rapid and specific method for detection and identification of pathogenic bacteria. Oligonucleotide microarray technology has been developed and widely used in the modern biology and life science research in recent years. It is featured by high throughput, low cost, and parallel detection of multiple genes simultaneously [9, 19, 20].

In the present study, a low-density oligonucleotide microarray was developed. Combined with multiplex PCR, virulence genes (ctx A, tcp A, stx1, stx2) and serotype specific genes (LPSgt for Vibrio cholerae O139 and uid A for E. coli O157:H7) are detected using the oligonucleotide microarray to detect and identify the pathogenic strains of Vibrio cholerae O139 and E. coli O157:H7 from clinical specimens simultaneously.

Results

Optimization of triplex PCR

The triplex PCR was used to amplify the target gene segments in E. coli O157:H7 and Vibrio cholerae O139. In multiplex asymmetric PCR reaction, the variation of the ratio of forward primer to reverse primer and concentrations impacted the amplification efficiency obviously. Therefore, the signal intensities of hybridization were highly related to the ratio and amount of forward primer to reverse fluorescent primer for each gene. After the optimization, three PCR products in one tube had good specificity and average amplification efficiency. The concentration of primers was showed in Table 1, and then the result of agarose gel electrophoresis was shown in Figure 1.

Table 1 Triplex PCR primers for amplifying the target genes in E. coli O157:H7 and Vibrio cholerae O139
Figure 1
figure 1

:

Screening of probes

The 60 candidate probes were spotted in an array format of 6 rows × 10 columns. The PCR products labeled by fluorescence were mixed with hybridization solution and then hybridized with the probe array. The suitable probe for each gene was selected according to the specificity and hybridization signal intensity, which was analyzed by using GenePix 4.0 software program. The screening result of candidate probes was shown in Figure 2, and then the hybridization signal intensity corresponding to each candidate probe was shown in Figure 3. The statistical analysis of the quantified signal intensities indicated: stx 1 No.7 probe, stx 2 No.10 probe, uid A No.9 probe, and LPSgt No. 10 probe, had stronger signal intensity than that of other probes, at any same level of the PCR template amount, and in the meantime there are no non-specific signals. No.9 probe of uid A was a shorter probe (19 bp) containing +93 mutant spot in the middle of the sequence. With comparison to the No. 10 probe (without mutant point), this probe was strictly specific to the single base mutant uidA gene of E. coli O157:H7, indicating its applicability in detection of the uid A gene mutation spot. No.3, No.4, and No.6 probes for ctx A had statistically proximal signal intensities. Nevertheless, No.4 probe was more specific than the others. No.2, No.5, and No.9 probes for tcp A also had statistically proximal signal intensities at higher level of DNA template amount; whereas, No.9 probe had apparently higher signal intensities than No.2, No.5 probes at lower level of DNA template amount.

As a result, the optimal detecting probes for the six target genes of two pathogens were selected as follows: stx 1 No.7 probe, stx 2 No.10 probe, uid A No.9 probe, ctx A No.4 probe, tcp A No.9 probe, LPSgt No.10 probe.

In addition, the bacterial universal probe was used as a positive control probes for verifying the PCR reaction was not inhibited by extraction impurities. And a plant gene segment with little sequence homology to the intestinal bacteria was chosen as a negative control probe. The final array format was shown as Figure 4. And the sequences of the optimal probe were listed in Table 2.

Figure 2
figure 2

:

Figure 3
figure 3

:

Figure 4
figure 4

:

Table 2 Oligonucleotide probe sequences for identification of E. coli O157:H7 and Vibrio cholerae O139

Specificity

The 149 strains of intestinal bacteria including various serotypes (parts as shown in Table 3) were detected under the optimal condition of triplex PCR and hybridization for testing the specificity of this oligonucleotide microarray. Two sets of triplex PCRs were performed to amplify bacterial DNA templates. Cy3 labeled PCR products were mixed and hybridized with the probe array fixed on the glass slides.

Table 3 part of the standard strains

It was shown that, 8 strains of E. coli O157:H7 had positive signal on stx 1, stx 2, and uid A probes. Two strains of E. coli O157: non-H7 had positive signals on stx 1 and stx 2 probes. Additionally, 3 strains of E. coli O157: non H7 and another serotype of Escherichia coli had signal on stx1 probe; 2 strains of E. coli O157: non H7 had signal on stx1 and stx2 probe, and furthermore E. coli O157: non-H7 had no signal on uid A probe. The results indicated that all the detected E. coli O157:H7 had both stx 1 and stx 2 toxin genes, whereas E. coli O157: non-H7 and other intestinal bacteria had one or both of the stx 1 and stx 2 toxin genes. However, the uid A probe can be used for identification of the O157:H7 from other intestinal bacteria accurately.

Seventy four strains of Vibrio cholerae O139 had positive signals on ctx A, tcp A, LPSgt probes; Vibrio cholerae (Ogawa and 569B) had positive signals on ctx A, tcp A probes. The results showed that ctx A, tcp A toxin genes may be detected in Vibrio cholerae O1 or O139 subtype. However, the probe specific to the unique region of LPSgt gene of Vibrio cholerae O139 was a strictly discriminating probe for Vibrio cholerae O139.

The fifty five strains of other intestinal bacteria and three non O1 non O139 Vibrio cholerae produces no detectable signal on the oligonucleotide microarray. The above results were shown in Table 4. Meanwhile, the hybridization images were shown in Figure 5, from which we could observe that the positive signals emerged orderly at the position corresponding to two pathogens from pure bacterial cultures; at the same time the signals of high intensity appeared at the position of positive control probes, and furthermore, no signals emerged at the position of negative control probes and blank probes.

Table 4 Test results of the 149 strains of intestinal bacteria using oligonucleotide microarray
Figure 5
figure 5

:

Sensitivity

We chose 149 standard strains of intestinal bacteria including various serotypes for determining the cutoff value of each probe. A large number of results from hybridization with positive strains, negative strains and blank control indicated that the signal intensity of negative strains and blank control was greatly lower than that of positive strains. Thereby, cutoff value of the probe was the average signal intensity from negative bacteria and blank control plus 2SD. Based on the cutoff value corresponding to each probe (Table 5), the sensitivity of this DNA microarray assay was evaluated.

The recombinant plasmids were quantified and prepared in 10-fold serial dilutions, which were used as the PCR templates to test the sensitivity of the oligonucleotide microarray. In the triplex PCR mixture, when the template plasmids were 103copies/μL, the PCR products can be detected both by using agarose gel electrophoresis and from the positive signal confirmed according to the cutoff value when hybridized with the detecting probe array; when the template plasmids were 102copies/μL, the PCR products, which can be detected only by hybridizing with the detecting probe array (the ratio of signal to noise was greater than 4), produce no visible bands on the same agarose gel electrophoresis. Furthermore, when the template plasmids were 10 copies/μL, PCR products can not be detected either by using agarose gel electrophoresis or by hybridization with the detecting probe array. The above results and the value of signal intensity corresponding to serial dilution were shown in Figure 6 and in Figure 7 respectively. Furthermore, the test limit of real time PCR was 102 copies/μL(data not shown). Similarly when serial dilution (10-fold) of two targets from 106~101cfu/mL were evaluated, the positive signals were observed with a detection limit of 103cfu/mL. The result of statistical analysis was shown in Figure 8. Meanwhile, the test limit of real time PCR and conventional microbiological methods was 103cfu/mL and 102cfu/mL respectively (data not shown).

Table 5 Cutoff value of the probe
Figure 6
figure 6

:

Figure 7
figure 7

:

Figure 8
figure 8

:

Detection of clinical specimens and double-blind mock samples

The clinical specimens were anus swabs collected from 60 patients in an epidemic Vibrio cholerae in Zhejiang Province, China. A total of 342 clinical specimens were detected by conventional microbiological methods, oligonucleotide microarray and fluorescent real-time PCR. The detection results were shown in Table 6.

Table 6 Vibrio cholera O139 testing result of the clinical specimens

It was shown that 89, 137, and 142 specimens were identified as Vibrio cholerae O139 with the methods of conventional culture, oligonucleotide microarray and fluorescent real-time PCR respectively. These results clearly indicated that the accuracy of oligonucleotide microarray was suitable for detection and identification of clinical specimen. Furthermore, through statistical analysis the p values (p < 0.05) were calculated in order to show that differences in the oligonucleotide microarray assay and conventional microbiological method were indeed significant in Table 6. The reason was that there were the target inactive organisms in the collected specimens in order that Vibrio cholerae O139 was detected positively using conventional culture.

Because most of clinical specimens collected were infected, we could not guarantee the validity of detecting E. coli O157:H7 in samples. Then, the 10 double-blind mock samples were prepared. From the results (Table 7) we observed that 8 of 10 mock samples were identified E. coli O157:H7 positive, and furthermore the above results were the same to double-blind results.

Table 7 E. coli O157:H7 testing result of the 10 double-blind mock samples

Discussion

Oligonucleotide microarray, based on multiplex PCR reaction, could simultaneously detect multiple target genes of a pathogen, and therefore identify pathogens accurately. An oligonucleotide microarray containing six probes was established in the present study, capable of identifying Enterohemorrhagic Escherichia coli O157:H7 and Vibrio cholerae O139 at the same time. The reliability of oligonucleotide microarray to identify a specific serotype of bacterium from other types of bacteria with the highly homologous origin was closely depended on the specificity of probe to the "genetic marker" in the discriminating gene. In this study, uid A and LPS gt were selected as the discriminating genes, and the T+93G spot mutation in uid A gene specific to E. coli O157:H7 and the unique region in LPS gt gene specific to Vibrio cholerae O139 were selected as the genetic markers. After screening the candidate probes with bacteria with negative or positive presence of the target genes, 6 probes were selected with the best specificity and sensitivity.

It is crucial for a suitable detection assay to avoid false negative and false positive results efficiently. Then in this article, we chosen 16S rDNA gene as an internal control referred to previous study in order to confirm the genomic DNA was present and the process of PCR was not affected by the inhibitors and then a segment with little sequence homology to the intestinal bacteria was chosen as a negative control probe. When two duplex PCR reactions carried out, we ran a parallel reaction for amplifying a universal 500 bp fragment from 16S rDNA gene. The hybridization images showed that the signals of high intensity appeared at the position of positive control probes for every PCR and hybridization except negative control reaction and no any signals appeared at the position of negative control probes and blank probes. Accordingly, the results illustrated that the detection results obtained from this DNA microarray assay were reliable and accurate.

The value of cutoff was used to evaluating the result obtained from DNA microarray. In this paper, we had determined the cutoff value of each probe by trial and error. As the above results shown, based on the cutoff value corresponding to each probe, this oligonucleotide microarray could detect 102 copies of plasmid DNA templates in the triplex PCR reaction and 103 cfu/mL of target pathogens. For specimen with lower amount of bacteria than the detection limit, such as E. coli O157:H7 having minimal infective dose as low as 10 cells of bacteria, the step of bacterial cultivation and enrichment prior to PCR amplification was prerequisite for the purpose of avoiding the false-negative results. The detection accuracy of the oligonucleotide microarray established in this study was obviously higher than that of the conventional microbiological method and at a proximal level as that of the real-time PCR assay. However, compared with real time PCR, the oligonucleotide microarray can detect the major toxin genes that contribute to the severity of the infectious diseases as well as the unique gene regions specific to the E. coli O157:H7 uid A and Vibrio cholera O139 LPS gt. Meanwhile, the above results also showed that the sensitivity of this assay was lower than that of the conventional microbiological method. However the culture method cost more time and operation steps, and furthermore the sensitivity of DNA microarray, 103 cfu/mL, was sufficient to detect clinical specimen.

As we known, the oligonucleotide microarray was more sensitive than that of PCR assay. The main reason was that the result of PCR was identified using agarose gel electrophoresis, which limited the sensitivity of PCR. However, the results of detection of clinical specimens indicated that the sensitivity of oligonucleotide microarray was similar to that of real-time PCR. This result was reasonable because the principle of real time PCR contained PCR and hybridization with specific probe.

As it is very difficult to choose PCR fragments with different size for target pathogens and optimize and establish a stable and reproducible multiplex PCR and real-time PCR, the oligonucleotide microarray based on multiplex PCR could produce more diagnostic information than the real-time PCR. It can detect multiple pathogens and multiple target genes simultaneously in one assay.

In conclusion, a rapid and reliable DNA microarray assay was developed for detecting and identifying E. coli O157:H7 and Vibrio cholera O139 simultaneously. The specific probes fixed on the slide were chose from the stx 1, stx 2, and uid A genes for E. coli O157:H7 and the ctx A, tcp A, LPSgt genes for Vibrio cholera O139 respectively. Furthermore, this DNA microarray could distinguish from E. coli O157:H7 and E. coli O157: non-H7, Vibrio cholera O139 and Vibrio cholera non-O139. Then, the above results obviously indicated that the assay described here was applied to epidemiological study, clinical diagnosis, surveillance of food and public health, control of infectious diseases. Meanwhile, this study was a commence fabricating a DNA microarray for detecting and identifying many genera or species of pathogens, and we are adding more genera or species of bacteria including food borne pathogen and acute human pathogenic microorganisms to this detection system in order to increase the range, accuracy and discriminatory power of simultaneous detection.

Methods

Bacterial strains and genomic DNA isolation from the anus swabs

The standard strains of E. coli O157:H7 and Vibrio cholerae O139 were provided by the National Institute for the Control of Pharmaceutical and Biological Products of China. The local standard strains of Vibrio cholerae O1 (569B), Vibrio cholerae Ogawa, Vibrio cholerae O139 and E. coli O157:H7 and the standard strains of some common intestinal bacteria and the clinical specimens were provided by the Center for Disease Prevention and Control of Zhejiang province, China. Part of the standard strains was listed in Table 3. The pathogens that isolated from clinical specimens were identified by the conventional microbiological methods [21, 22]. The double-blind 10 mock samples infected by E. coli O157:H7 were prepared. The genomic DNA from clinical samples was extracted by centrifugation as previously described [23]. Meanwhile DNA of the standard strains was extracted with UNIQ-10 column Genomic DNA Minipreps Kit (Sangon Co., LTD Shanghai, China), according to the manufacturer's instructions. Purified genomic DNAs were stored at -20°C in TE.

Primers and probes

Based on references and published gene sequences in GenBank, stx 1, stx 2 and uid A genes were selected for E. coli O157:H7, ctx A, tcp A, LPSgt genes for Vibrio cholerae O139. Various sequences of each gene were collected and aligned by software Vector NTI Suite 9/AlignX. Primers and probes were designed using software Primer 5.0. The specificity of sequences was analyzed by BLAST GenBank. The 10 candidate probes were designed for each gene (totally 60 candidate probes), 19–60 mer in length. The Tm values of six primers and according to probes were approximately identical, and then the length of each PCR product was less than 500 bp. 16S rDNA gene was chosen as an internal control for verifying that genomic DNA templates of pathogens were present and the PCR reaction carried out successfully. Based on the previous study, a 500-bp fragment was obtained through PCR amplification using 16S-F1 (CGCTGGCGGCAGGCCTAACACATGC) and 16S-R1 (CGCGGCTGCTGGCACGGAGTTAGCC), and then the bacterial universal probe (ACTGAGACACGGTCCAGACTCCTACGGGAGGCAGCAGTAGGGAATATTG) was chosen as a marker for checking validity of internal control [24]. The oligonucleotide probes were modified with amino residue at 3' end. The reverse primer was labeled with fluorescent dye Cy3 at 5' end. The sequences of primers and probes were shown in Table 1 and Table 2 respectively.

PCR amplification

A volume of 20 μL conventional PCR mixture contains: 0.1 μmol/L the forward primer, 1.0 μmol/L the reverse primer, 100 μmol/L dNTPs, 50–100 ng DNA template, 1× PCR buffer and 1.5 U Taq polymerase (Promega). PCR products were amplified in a thermal cycler (PTC-100™ programmable thermal controller, MJ. research Inc) under the following condition: initial denaturation(5 min at 94°C) followed by 40 cycles of denaturation (30 sec at 94°C), annealing(30 sec 62°C) and extension(30 sec at 72°C). A final extension step was carried out for 5 min at 72°C, and 4°C forever. Through many experiments the optimal final concentration of primers in triplex PCR reaction was determined. The PCR condition and concentration of each component for 16S rDNA gene referred to the previous study [24].

Construction of recombinant plasmid as standard template

DNA templates were extracted from standard strains of E. coli O157:H7 W933 and Vibrio cholerae O139 M045 respectively, which were amplified using conventional PCR with unlabelled primers. The PCR products were purified, and then inserted into pGEM-T vectors (Promega). Consecutively, the recombinant products were transformed into Escherichia coli DH5α (Promega), and incubated overnight at 37°C with shaking. Recombinant plasmids were screened using the T7 and SP6 primers and extracted using Promega Plasmid Extracting Kit, which procedure was according to the manual. After purification, the insert DNA fragments were identified through sequencing using automatic DNA sequencer (CEQ-2000). The number of plasmid copies was counted as previously described [25]. The plasmid was 10-fold serial diluted and stored at -20°C for use as PCR template.

Preparation of the oligonucleotide microarray

The 3' end amino-modified probes were diluted to a final concentration of 50 μmol/L in spotting solutions (3 × SSC and 0.01% SDS) and were transferred into 384-well micro-titer plates in volumes of 10 μL. The probe solutions were spotted to aldehyde-coated glass slides (CEL Associates) with a microarray printer (Cartisan), which deposits 0.5 nL at each spotting site, resulting in spots of 200 μM in diameter. The humidity during spotting was 90% and the temperature kept at 23°C. After spotting, slides were incubated for another 2 h under the same conditions and stored at room temperature for at least 24 h before use.

Hybridization and signal detection

The Cy3-labeled PCR products were mixed with the hybridization solution (6 × SSC, 1 × Denhard, 0.2% SDS), and 10 μL of the hybridization solution was transferred to the hybridization area on the glass slide. The slide was incubated in 42°C water bath for 1 h in a tightly-sealed hybridization chamber. After incubation, the slide was washed sequentially in washing solution A (1 × SSC, 0.2% SDS), washing solution B (0.2 × SSC) and washing solution C (0.1 × SSC) for 1 min each.

The glass slides were scanned using the GenePix 4000B (Axon), with excitation at 540 nm and emission at 570 nm (Cy3). Sixteen-bit TIFF images of 10 micrometers resolution were analyzed with software GenePix Pro 4.0. The signal intensity is displayed according to spot color, whose order from high to low is white, red, yellow, green, and blue. After the removal of local background, the average signal intensity of each probe was calculated. The cutoff value was evaluated in order to confirm whether the target was considered to be positive or not.

Assay sensitivity

The sensitivity was evaluated according to serial dilution (10-fold) from 104~101 copies/μL. Meanwhile, according to Jin et al[24], the sensitivity about the amount of bacteria in clinical specimen was determined. Each dilution series of genomic DNA were mixed with a natural background of genomic DNA from stool samples of healthy volunteers. The genomic DNA of stool samples was extracted as shown above. After the whole operation, two kinds of sensitivity were determined through signal intensity according to cutoff value. Additionally, the sensitivity of real time PCR (In real time PCR, the fluorescent probe detected the same unique region in LPS gt gene as the detecting probe of the oligonucleotide microarray) (DaAn Gene Co., Ltd, Guangzhou, China) and conventional microbiological methods was determined in order to compare the sensitivity of this assay with other methods.

Statistical analysis

Statistical analysis in this paper was made with SPSS for Windows software (version 11.5, Chicago, Il, USA).

References

  1. Ministry of Health P.R. China: Statistics of legal infectious disease broke out in 2001–2006. 2006, [http://www.moh.gov.cn]

    Google Scholar 

  2. Song Myong Joon, Vo-Dinh Tuan: Miniature biochip system for detection of Escherichia coli O157:H7 based on antibody-immobilized capillary reactors and enzyme-linked immunosorbent assay. Analytica Chimica Acta. 2004, 507: 115-121. 10.1016/j.aca.2003.11.072.

    Article  CAS  Google Scholar 

  3. Patrick Fach, Perelle S, Grout J, Dilasser F: Comparison of different PCR tests for detecting Shiga toxin-producing Escherichia coli O157 and development of an ELISA-PCR assay for specific identification of the bacteria. Journal of Microbiological Methods. 2003, 55: 383-392. 10.1016/S0167-7012(03)00172-6.

    Article  Google Scholar 

  4. Fortin Nathalie, Mulchandani A, Chen W: Use of Real-Time Polymerase Chain Reaction and Molecular Beacons for the Detection of Escherichia coli O157:H7. Analytical Biochemistry. 2001, 289: 281-288. 10.1006/abio.2000.4935.

    Article  PubMed  CAS  Google Scholar 

  5. Call DR, Brockman FJ, Chandler DP: Detecting and genotyping Escherichia coli O157:H7 using multiplexed PCR and nucleic acid microarrays. International Journal of Food Microbiology. 2001, 67: 71-80. 10.1016/S0168-1605(01)00437-8.

    Article  PubMed  CAS  Google Scholar 

  6. Fagan PK, Hornitzky MA, Bettelheim KA, Djordjevic SP: Detection of shiga-like tox (stx1 and stx2), intimin (eaeA), and enterohemorrhagic Escherichia coli (EHEC) hemolysin (EHEC-hlyA) genes in animal feces by multiplex PCR. Appl Environ Microbiol. 1999, 65: 868-872.

    PubMed  CAS  PubMed Central  Google Scholar 

  7. Cebula TA, Payne WL, Feng P: Simultaneous identification of strains of Escherichia coli serotype O157:H7 and their Shiga-toxin type by mismatch amplification mutation assay-multiplex PCR. J Clin Microbiol. 1995, 33: 248-250.

    PubMed  CAS  PubMed Central  Google Scholar 

  8. Law D: Virulence factors of Escherichia coli O157 and other Shiga toxin-producing E. coli. Appl Microbiol. 2000, 88: 729-745. 10.1046/j.1365-2672.2000.01031.x.

    Article  CAS  Google Scholar 

  9. Guan J, Levin RE: Quantitative detection of Escherichia coli O157:H7 in ground beef by the polymerase chain reaction. Food Microbiol. 2002, 19: 159-165. 10.1006/fmic.2001.0477.

    Article  CAS  Google Scholar 

  10. Chi-Fang Wu, Valdes JJ, Bentley WE, Sekowski JW: DNA microarray for discrimination between pathogenic O157:H7 EDL933 and non-pathogenic Escherichia coli strains. Biosensors and Bioelectronics. 2003, 19: 1-8. 10.1016/S0956-5663(03)00133-7.

    Article  Google Scholar 

  11. Yoshitomi KJ, Jinnemana KC, Weagant SD: Optimization of a 30-minor groove binder-DNA probe targeting the uidA gene for rapid identification of Escherichia coli O157:H7 using real-time PCR. Molecular and Cellular Probes. 2003, 17: 275-280. 10.1016/j.mcp.2003.07.001.

    Article  PubMed  CAS  Google Scholar 

  12. Albert MJ, Ansaruzzaman M, Bardhan PK, Faruque ASG, Faruque SM, Islam MS, Mahalanabis D, Sack RB, Salam MA, Siddique AK, Yunus M, Zaman K: Large epidemic of cholera-like disease in Bangladesh caused by Vibrio cholerae O139 synonym Bengal. Cholera Working Group, International Centre for Diarrhoeal Diseases Research, Bangladesh. Lancet. 1993, 342: 387-10.1016/0140-6736(93)91906-3.

    Article  Google Scholar 

  13. Hoshino Katsuaki, Yamasaki S, Mukhopadhyay AK, Chakraborty S, Basu A, Bhattacharya SK, Nair GB, Shimada T, Takeda Y: Development and evaluation of a multiplex PCR assay for rapid detection of toxigenic Vibrio cholerae O1 and O139. FEMS Immunology and Medical Microbiology. 1998, 20: 201-207. 10.1111/j.1574-695X.1998.tb01128.x.

    Article  PubMed  CAS  Google Scholar 

  14. Robert-Pilot Annick, Baron AS, Lesne J, Fournier JM, Quilici ML: Improved specific detection of Vibrio cholerae in environmental water samples by culture on selective medium and colony hybridization assay with an oligonucleotide probe. FEMS Microbiology Ecology. 2002, 40: 39-46. 10.1111/j.1574-6941.2002.tb00934.x.

    Article  Google Scholar 

  15. Bhuiyan NA, Qadri F, Faruque AS, Malek MA, Salam MA, Nato F, Fournier JM, Chanteau S, Sack DA, Balakrish Nair G: Use of dipsticks for rapid diagnosis of cholera caused by Vibrio cholerae O1 and O139 from rectal swabs. J Clin Microbiol. 2003, 41 (8): 3939-3941. 10.1128/JCM.41.8.3939-3941.2003.

    Article  PubMed  CAS  PubMed Central  Google Scholar 

  16. Said Bengu, Smith HR, Scotland Syivia: Detection and differentiation of gene for toxin co-regulated pili(tcpA) in Vibrio cholerae non-O1 using the polymerase chain reaction. FEMS Microbiology Letters. 1995, 125: 205-210. 10.1111/j.1574-6968.1995.tb07359.x.

    Article  PubMed  CAS  Google Scholar 

  17. Carter RM, Mekalanos JJ, Jacobs MB, Lubrano GJ, Guilbault GG: Quartz crystal microbalance detection of Vibrio cholerae O139 serotype. Journal of Immunological Methods. 1995, 187: 121-125. 10.1016/0022-1759(95)00176-B.

    Article  PubMed  CAS  Google Scholar 

  18. Call DR, Borucki MK, Loge FJ: Detection of bacterial pathogens in environmental samples using DNA microarrays. Journal of Microbiological Methods. 2003, 53: 235-243. 10.1016/S0167-7012(03)00027-7.

    Article  PubMed  CAS  Google Scholar 

  19. Bang-Xing Hong, Jiang LF, Hu YS, Fang DY, Guo HY: Application of oligonucleotide array technology for the rapid detection of pathogenic bacteria of foodborne infections. Journal of Microbiological Methods. 2004, 58: 403-411. 10.1016/j.mimet.2004.05.005.

    Article  Google Scholar 

  20. WJ Wilson, Strout CL, DeSantis TZ, Stilwell JL, Carrano AV, Andersen GL: Sequence specific identification of 18 pathogenic microorganisms using microarray technology. Molecular and Cellular Probes. 2002, 16: 119-127. 10.1006/mcpr.2001.0397.

    Article  Google Scholar 

  21. Evan AS: Bacterial infections of humans. Edited by: Evan AS. 1998, New York, NY: Plenum Medical Book Company

    Chapter  Google Scholar 

  22. Miliotis MD: International handbook of foodborne pathogens. Edited by: Miliotis MD. 2003, New York, Basel: Marcel Dekker

    Chapter  Google Scholar 

  23. Wang Rong-Fu, Beggs ML, Robertson LH, Ceriglia CE: Design and evaluation of oligonucleotide-microarray method for the detection of human intestinal bacteria in fecal samples. FEMS Microbiology Letter. 2002, 213: 175-182. 10.1111/j.1574-6968.2002.tb11302.x.

    Article  CAS  Google Scholar 

  24. Da-Zhi-Jin , Siyuan-Wen , Suhong-Chen , Lin Feng, Shengqi-Wang : Detection and identification of intestinal pathogens in clinical specimens using DNA microarrays. Molecular & Cellular Probes. 2006, 20: 337-347. 10.1016/j.mcp.2006.03.005.

    Article  Google Scholar 

  25. Sambrook J, Russell DW: Molecular Cloning: A Laboratory Manual. Edited by: Sambrook J, Russell DW. 2002, Cold Spring Harbor Laboratory Press, 3

    Google Scholar 

Download references

Acknowledgements

Supported by the National Key Technologies R & D Program of China during the 10th Five-Year Plan Period (2003BA712A03-09).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Feng Lin or Sheng-Qi Wang.

Additional information

Authors' contributions

The author's current institute is Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, China. Tel/Fax: 86-571-87235092; E-mail: dazhijin@163.com.

The authors wish it to be known that, in their opinion, the first two authors should be regarded as joint First Authors.

D-ZJ and X-JX carried out the all the experiments; S-HC participated in the design of oligonucleotide mocriarray; S-YW drafted the manuscript; ZZ and FL collected the clinical specimens; X-EM performed the statistical analysis; S-QW designed and conceived of all the study and participated in its coordination. All authors read and approved the final manuscript.

Da-Zhi Jin, Xiao-Jing Xu contributed equally to this work.

Authors’ original submitted files for images

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Jin, DZ., Xu, XJ., Chen, SH. et al. Detection and identification of enterohemorrhagic Escherichia coli O157:H7 and Vibrio cholerae O139 using oligonucleotide microarray. Infect Agents Cancer 2, 23 (2007). https://doi.org/10.1186/1750-9378-2-23

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1750-9378-2-23

Keywords